The condensers and cooling systems involved
in condensing the exhaust steam from a steam turbine and transferring the waste
heat away from the power station.
The environmental effects of these systems will also be briefly discussed.
Condensers
The function of the condenser is to condense exhaust steam from the steam turbine
by rejecting the heat of vaporisation to the cooling water passing through
the condenser. The temperature of the condensate determines the pressure
in the steam/condensate side of the condenser. This pressure is called the
turbine backpressure and is usually a vacuum. Decreasing the condensate temperature
will result in a lowering of the turbine backpressure. Note: Within limits,
decreasing the turbine backpressure will increase the thermal efficiency
of the turbine.
The condenser also has the following secondary functions:
The condensate is collected in the condenser hot well, from which the condensate
pumps take their suction;
Provide short-term storage of condensate;
Provide a low-pressure collection point for condensate drains from other systems
in the plant; and
Provide for de-aeration of the collected condensate.
A typical power plant condenser has the following functional arrangement.
![]() |
Large power plant condensers are usually 'shell and tube' heat exchangers.
These types of condensers are also classified:
As single pressure or multi-pressure, depending on whether the cooling water
flow path creates one or more turbine backpressures;
By the number of shells (which is dependent on the number of low-pressure turbine
casings); and
As either single pass or two-pass, depending on the number of parallel water
flow paths through each shell.
Other types of condensers are:
Plate types consisting of a series of parallel plates that provide paths for
the steam and the cooling water. Plate condensers are used mainly for smaller
power plants; and
Direct contact types where the cooling water is sprayed directly into the steam.
This type of condenser is used in applications where the cooling water is the
same quality as the steam condensate. Systems that have dry cooling (described
in a following section) sometime use direct contact condensers.
The parts of shell and tube condensers and plate condensers involved in the
transfer of heat from the steam and condensate to the cooling water should
have the following properties:
Be resistant to corrosion from both the steam/condensate and the cooling water;
Have a minimal resistance to the flow of heat from the steam/condensate through
the material into the cooling water; and
Provide mechanisms to remove organic and inorganic deposits on the heat transfer
surfaces in contact with the cooling water.
Types of Cooling Systems
Some power stations have an open cycle (once through) cooling water system
where water is taken from a body of water, such as a river, lake or ocean,
pumped through the plant condenser and discharged back to the source. Inland
plants away from large water bodies prefer to use closed cycle wet cooling
system with wet cooling towers. Plants in remote dry areas without economic
water supplies use closed cycle dry cooling systems that do not require water
for cooling. Hybrid cooling systems are used in particular circumstances.
The type of cooling system used is therefore heavily influenced by the location
of the plant and on the availability of water suitable for cooling purposes.
The selection process is also influenced by the cooling system's environmental
impacts (refer to a following section for a brief discussion on this topic).
Open Cycle Cooling Systems
Open cycle (once through) cooling systems may be used for plants sited beside
large water bodies such as the sea, lakes or large rivers that have the ability
to dissipate the waste heat from the steam cycle. In the open system, water
pumped from intakes on one side of the power plant passes through the condensers
and is discharged at a point remote from the intake (to prevent recycling
of the warm water discharge).
![]() |
Open systems typically have high flow rates and relatively low temperature
rises to limit the rise in temperature in the receiving waters. A typical 350
MW unit would have a flow of some 15000 to 20000 L/s.
Lake cooling systems are a variant on a true open system as the temperature
of the lake is increased from the circulation of the warm water. Environmental
requirements have become more stringent on the allowable rise in temperature
of the receiving waters, so that closed systems are now more commonly used
in Australia.
Open Cycle with Helper Cooling Tower
In this system, cooling towers are installed on the discharge from open systems
in order to remove part of the waste heat, so that the load on the receiving
waters is contained within pre set limits. Systems with helper cooling towers
are common in Germany and France where cooling supplies are drawn from the
large rivers. The helper towers are used in the warmer summer periods to
limit the temperature of the discharged cooling water, usually to less than
30º C.
![]() |
Closed Cycle Wet Cooling Systems
In closed cycle wet cooling systems, the waste energy that is rejected by the
turbine is transferred to the cooling water system via the condenser. The waste
heat in the cooling water is then discharged to the atmosphere by the cooling
tower.
In the cooling tower, heat is removed from the falling water and transferred
to the rising air by the evaporative cooling process. The falling water is
broken up into droplets or films by the extended surfaces of the tower 'fill'.
This 'fill' in the later Queensland towers is manufactured from plastic.
Some of the warm water, typically 1 to 1.5% of the cooling water flow, is
transferred to the rising air, and this is visible in the plume of water vapour
above towers in times of high humidity. The evaporation rates of the Queensland
350 MW cooling systems are typically 1.8 litres of water per kWh of power generated.
![]() |
The major components of a closed cycle wet cooling water system are:
Cooling towers - two types are commonly used, concrete natural draught towers
and mechanical draught towers; and
Pumps and pipes.
Natural Draught Towers
Concrete natural draught towers have a large concrete shell. The heat exchange
'fill' is in a layer above the cold air inlet at the base of the shell as shown
in the tower sectional view. The warm air rises up through the shell by the
'chimney effect', creating the natural draught to provide airflow and operate
the tower. These towers therefore do not require fans and have low operating
costs.
The cooling towers have two basic configurations for the directions of the
flow of air in relation to the falling water through the tower fill:
The counter-flow tower where the air travels vertically up through the fill
(a diagram of this type of tower is shown below); and
The cross-flow tower where the air travels horizontally through the fill.
Natural draught towers are only economic in large sizes, which justifies the
cost of the large concrete shell. Natural draught towers are the most common
towers for large generating units in Europe, South Africa and Eastern USA.
They are not used in the drier areas of Western USA, as their performance is
better suited to cooler and more humid areas. This performance limitation also
limits their use in Australia.
![]() |
Mechanical Draught Cooling Towers
In mechanical draught cooling towers, large axial flow fans provide the airflow.
While fans have the disadvantage of requiring auxiliary power, typically
1.5 to 2.0 MW for a 420 MW unit, fans have the advantage of being able to
provide lower water temperatures than natural draught towers, particularly
on hot dry days.
Mechanical draught towers are used exclusively in central and western USA
as their climate can vary from freezing to hot with low humidity, and the
mechanical towers can provide a more controlled performance over this wide range
of conditions.
The most common materials used in large mechanical draught cooling towers
are timber for the framing and plastic for the cladding and internals.
Pumps and Pipes in a Cooling Water System
Circulating water pumps supply cooling water at the required flow rate and
pressure to the power plant condenser and the plant auxiliary cooling water
heat exchangers. These pumps are required to operate economically and reliably
over the life of the plant.
The three types of pumps commonly used for circulating water service are 'vertical
wet pit', 'horizontal dry pit' and 'vertical dry pit'. For once through systems,
vertical wet pit pumps are in common usage. For re-circulating cooling systems,
vertical wet pit and horizontal dry pit are used about equally, with occasional
use of vertical dry pit pumps.
Circulating water piping carries the cooling water from the circulating water
pumps to the condenser and returns the water to the cooling tower or discharge
structure. The large flow rates associated with circulating water systems typically
require the use of large diameter piping in the range 900 mm to 2400 mm diameter.
The design of the pipework must consider the environment internal to the pipe
as well as the external environment. Pipe materials used include steel, fibre
reinforced plastic and reinforced concrete. The large water requirement generally
makes it uneconomical to use high quality water sources. The source of water
for the plant generally depends on the plant's location. Coastal sites generally
use seawater or brackish water as the circulating water source, either by
pumping directly from the sea or extracting the water from the local bores.
Water from many sources can contain high concentrations of corrosive contaminants.
Any pipe materials considered must include measures to protect the pipe for
the service life of the plant. For example, carbon steel pipes in seawater
service require either an internal coating, or a cathodic protection system,
or both. Concrete pipes may require a dense concrete mix to withstand chloride
attack. These protective measures significantly increase the capital cost
of an installation such that it can be as economical to install fibre reinforced
plastic pipe to obtain the same service life. As existing water sources become
strained and new water sources more scarce and expensive to develop, the
quality
of circulating water in future power plants is expected to decline further.
This will increase the trend towards corrosion resistant piping materials.
Closed Cycle Dry Cooling Systems
Dry cooling systems are used where there is insufficient water, or where the
water is too expensive to be used in an evaporative system. Dry cooling systems
are the least used systems as they have a much higher capital cost, higher
operating temperatures, and lower efficiency than wet cooling systems.
In
the dry cooling system, heat transfer is by air to finned tubes. The minimum
temperature that can
be theoretically provided is that
of the dry air, which
can be regularly over 30º C and up to 40º C on typical summer afternoons
in Queensland. Compare this to wet cooling towers, which cool towards the wet
bulb temperature, which is typically 20º C on summer afternoons. The steam
condensing pressures and temperatures of a dry cooled unit are significantly
higher than a wet cooled unit, due to the low transfer rates of dry cooling
and operation at the dry bulb temperature.
There are two basic types of dry cooling systems:
1. The direct dry cooling system; and
2. The indirect dry cooling system.
Variations on the full dry and full wet systems are hybrid systems, which may
be wet with some dry or dry with part wet.
Direct Dry Cooling System
In the direct dry system, the turbine exhaust steam is piped directly to the
air-cooled, finned tube, condenser. The finned tubes are usually arranged
in the form of an 'A' frame or delta over a forced draught fan to reduce
the land area. The steam trunk main has a large diameter and is as short
as possible to reduce pressure losses, so that the cooling banks are usually
as close as possible to the turbine.
The direct system is the most commonly used as it has the lowest capital cost,
but significantly higher operating costs. The power required to operate the
fans of this system is several times that required for wet towers, being typically
4 to 5 MW for a 420 MW unit.
![]() |
Indirect Dry Cooling System
Indirect dry cooling systems have a condenser and turbine exhaust system as
for wet systems, with the circulating water being passed through finned tubes
in a natural draught cooling tower. The water pipework allows the towers
to be sited away from the station.
A variation on this type of indirect system is the system that uses a direct
contact condenser in place of the traditional tube type condenser. In the spray
condenser, the water from the cooling cycle mixes with the boiler water. The
maintenance of the water quality to suit all circuits is critical to the successful
operation of the system.
![]() |
Hybrid Systems
There are two common hybrid systems, which have been developed to overcome
some of the disadvantages of the full wet and full dry systems.
Wet with Part Dry
One of the problems with wet towers is that in cold and humid climates the
towers plume, can create fog. In the part dry or plume abatement tower, a dry
section above the wet zone provides some dry cooling to the exhaust plume to
remove the condensing water vapour. These towers are common in Germany and
England where environmental problems with mechanical towers have arisen.
Dry with Part Wet
Problems with full dry towers are centred on loss of performance in hot weather.
With the part wet towers, there is provision for water sprays to evaporatively
cool the finned tubes for short periods of extreme temperature.
Environmental Effects of Cooling Systems
All the heat transferred from the exhaust steam to the cooling system eventually
finds its way into the earth's atmosphere.
In the once-through cooling water system, heat is removed from the steam turbine
and transferred to the source body of water. The heat is then gradually transferred
to the atmosphere by evaporation, convection and radiation. However, this waste
heat transfer process may negatively affect the body of water buy increasing
the temperature of the water.
In a re-circulating cooling system, the cooling water carries waste heat removed
from the steam turbine exhaust to the cooling tower, which rejects the heat
directly to the atmosphere. Because of this direct path to the atmosphere,
surrounding water bodies typically do not suffer adverse thermal effects. Some
water is discharged from the cooling water system to maintain the concentration
of chemicals in the cooling water below licensed limits. This water is often
discharged to surrounding watercourses.
In dry cooling systems, the waste heat is transferred directly to the atmosphere.